Mobile/Whats app/Wechat: +86 136 1862 9837
Hot keywords: Relay Tester Cable Fault Detector CT PT Tester SF6 Tester Transformer Tester
Send Inquiry
Fill this form and we'll get back to you soon.
RELATED PRODUCTS
Power:AC220V±10% 50HZ Output voltage accuracy :±(1.0%R±2D) Output current accuracy : ±(1.0%R±2D) Ripple factor :≤0.5% Working mode :Intermittent use, 30 minutes under rated load
Power :AC220V±10%,50Hz±1% Output voltage indication accuracy :<1 class 0.75 times output voltage indication accuracy :<1 class,With latch Altitude :1500m below Way of working :Intermittent use for 30 minutes
Power supply:Single phase :220V Or three phase :380V±10%, Frequency:50Hz±5% AC effective value Rated output voltage:≤0~220kV Output frequency :30~300Hz Frequency adjustment :0.1Hz
Frequency Power Source: 3kv~60kv Divider: 50kv~800kv Rated Output Voltage:0~1000kv Power Supply: single phase220V / 3 phase 380V
Power:AC220V±10%, 50Hz±1% Ripple factor : ≤0.5% 0.75 times output voltage indication accuracy : <1,with latch function Working mode :discontinuously work for 30 minutes Altitude :<1500m
Withstanding Voltage Test Output Voltage: AC: 0.05~5.00KV DC: 0.05~6.00KV Current Test Range: AC: 0.00~10.00mA DC: 0.00~5.00mA
Withstanding Voltage Test Output Voltage: AC: 0.05~5.00KV DC: 0.05~6.00KV Current Test Range: AC: 0.00~10.00mA DC: 0.00~5.00mA
Power Requirements: AC:220V±10% 50Hz/60Hz ± 3Hz Test Accuracy: ± (5%+3 words) Test Time: (0.0~999)s 0.0=continuous test Transformer Capacity: 100VA, 500VA, 1000VA. Interface of PLC: Optional
Capacity: 0.5KVA Alarm current(mA):0.5~20 Test time: 1~99s Power supply: 220V±10%, 50Hz Humidity: ≤80%
Monitoring function: output current, meter voltage, timing. Capacity :2/3/5/10/15... Phase :1/2 Operation :Manual/Electric Altitude :< 2000m
Power Supply: AC220V ±15%, 50Hz±2Hz Measuring accuracy: 0.5%±2d Measuring range: 0~9999 Display: LCD Display
Transformer Type: Gas Type Voltage Class: 10KV-300KV Capacity range: 1-500KVA Product Type: AC/DC No-load current: <7% Impedance voltage:≤8%
Type: Gry Type Impedance voltage: ≤12% Output voltage waveform: sine wave Capacity: 1.5~30KVA Input Voltage: 200 or 400V Output Voltage: 50~120KV
Type:Oil Immersed Capacity:1.5~300KVA High Voltage: 50~300KV High Current: 30~3000mA
Power voltage: AC 220V Capacity: 0-5KVA Output voltage: 0-250V Voltage accuracy: ±0.5 Current accuracy: ±0.5
Temperature: 0~4℃ Relative temperature: <85% Altitude: <1000m Workplace should be free of gases etc
Use: non-fixed placement, Altitude: not less than 2000m Highest temperature:+40 ° C Lowest temperature -25 ° C Earthquake intensity 8 degrees
Rated Voltage: 30KV-80KV. Output frequency: 0.1Hz、0.05Hz、0.02Hz Power: AC 50 Hz,220V ±5% Fuse: 5A-20A Measurement accuracy:2.5% Voltage wave form distortion: ≤3%
Large test range: 0.1Hz, 0.05Hz and 0.02hz Multi frequency selection, large test range Comprehensive protection: multiple protection over-voltage protection, over- current protection at high and low voltage sides), rapid action (when acting)
Input current: 7.6A Output voltage: 0-300V, 150Hz Harmonic distortion ≤5% Output current: 5A Output capacity: 5KVA
Power voltage :AC 220V Capacity:5KVA Output voltage :0—250V High Voltage output: 0-50KV Operation mode: Auto, manual
Power voltage :AC 220V Capacity :3KVA Output voltage :0—250V Voltage accuracy/Current accuracy :±1.0 Operation mode :Auto,manual Output voltage :0—250V
Input Voltage: AC220V, 50Hz Output Voltage: 0~30KV Capacity: 3KVA Numbers: 3 pairs each test Glove/boot test bed: 80kg Frequency voltage withstand test bed: 70kg
Input Voltage: AC220V, 50Hz Output Voltage: 0~30KV Capacity: 3KVA Test quantity: 6 each time User interface: LCD, with printer
Ratio: 1000:1 Insulating medium: dry type dielectric material AC Measuring method: real effective value measurement Voltmeter range: Low: 0-20kv; High:0-50kv Accuracy: AC:1.0% ; DC:0.5%
Capacity: 3-60KVA Auto transformer adjusts freely
Amplitude measurement range :(-100dB)~(+20dB) Amplitude measurement accuracy :0.1dB Scan frequency accuracy :<0.01% Signal input impedance :1MΩ Signal output impedance : 50Ω
Power supply :AC220V±10%; 50HZ±2% Power factor :0.1~0.9999 Voltage :0.1~600V Current :0.1~200A Relative error :±(0.2% reading +0.1% measurement range)
Display: 4.0inch RGB LCD screen Headphone: 8ohm minimum Controller: ARM Sensor transmission impedance: 5mV/mA TEV Measurement range: 0-60dBmV UHF Detection frequency band: 300~1500MHz
Partial discharge peak display: 0~10000pC Measurement channels: Channels A and B Detection sensitivity: 0.1pC Measuring frequency band: 3dB band width 10kHz~300kHz Gain dynamic range: 120dB
Output current: 1A, 5A, 10A Measuring range: 500uΩ~50kΩ Accuracy: ±(Reading X 0.2%)+2 words) Maximum resolution: 0.1uΩ Charging current: ≤3A Charging voltage: 16.8V
Output current: select current automatically (maximum 20 A) Range ability: 0-100 Ω Accuracy: 0.2%±2 Minimum resolution: 0.1 μΩ Altitude: ≤1000meters
Power :AC 220V±22V,50Hz±2 Hz Data storage capacity :150 groups Measurement :Single phase (two phase) /Three phase Current gear :1A 5A 10A 20A 40A Max resolution :0.1μΩ Accuracy :±0.2%+2d (full range)
Power :AC 220V±22V,50Hz±2 Hz Data storage capacity :150 groups Accuracy :±0.2%+2d (full range) Max resolution :0.1μΩ Measurement :Single phase (two phase) /Three phase
Working voltage :DC 11V~14V AC 220V Constant current source :1A(1μΩ~20mΩ、20mΩ~200mΩ、0.2Ω~2Ω) 100mA(2Ω~20Ω) 10mA(20Ω~200Ω) 1mA(200Ω~2kΩ) Max resolution :1μΩ Measuring accuracy :Class 0.2
Working voltage :DC 11V~14V ;AC 220V Power Dissipation :≤15W Resolution :1μΩ Measuring accuracy :Class 0.2 Wide measurement range :resistance measurement range 1μΩ ~ 2KΩ, wide range
Working voltage :DC 12V~16.8V AC 220V Measuring accuracy :±(0.2%+2d) Resolution :1μΩ Constant current source :3A(1μΩ~20mΩ、20mΩ~200mΩ、0.2Ω~2Ω) Power Dissipation :≤15W
Power supply :AC220V±22V,50Hz±2Hz Fuse 5A Maximum Power Dissipation :300W Max resolution :0.1μΩ Display mode :LCD display Accuracy :±0.2%(full range±2 digit) Measurement current :1mA,10mA,1A,5A,10A
Measure current :1A, 5A, 10A, 20A Accuracy :±0.2%(full range) Data Storage :255 Maximum resolution :0.1μΩ Power supply :AC 220V±22V,50Hz±2 Hz Fuse 5A Maximum Power Dissipation :300W Test current:10A
Power supply :AC 220V±22V,50Hz±2 Hz Fuse 5A Maximum Power Dissipation :1200W Inputting10A test current Maximum resolution :0.1μΩ Display :LCD Resistance display: 4 1/2 bits Accuracy :±0.2%(full range) Measure current :2.5A, 5A, 10A, 20A, 40A
Output current:<5mA ,1A,2.5A,5A Resolution:0.1μΩ Range:100Ω-20KΩ (<5mA) 1Ω-250Ω (40mA) 100mΩ-50Ω (200mA) 5mΩ-10Ω (1A) 1mΩ-2Ω (5A) Accuracy:±(0.2%+2 Readings)
Output current:<5mA ,1A,2.5A,5A ,10A,20A Resolution:0.1μΩ Range: 100μΩ~1Ω (20A) 500μΩ~2Ω (10A) 1mΩ~4Ω (5A) 2mΩ~8Ω (2.5A) 5mΩ~20Ω (1A) 10Ω~20KΩ (<5mA) Accuracy:±(0.2%+2 Readings)
Output current:<5mA ,2.5A,5A ,10A,20A,40A, Resolution:0.1μΩ Range:50μΩ~500mΩ (40A) 100μΩ~1Ω (20A) 500μΩ~2Ω (10A) 1mΩ~4Ω (5A) 2mΩ~8Ω (2.5A) 10Ω~20KΩ (<5mA) Accuracy:±(0.2%+2 Readings)
Power supply :AC 220V±22V,50Hz±2 Hz ,Fuse 5A Measure current :2.5A, 5A, 10A, 20A, 50A Accuracy :±0.2%(full range) Data Storage :255 Display :LCD Resistance display: 4 1/2 bits Maximum resolution :0.1μΩ Maximum Power Dissipation :1500W Inputting10A test current
Power supply :AC 220V±22V,50Hz±2 Hz ,Fuse 5A Measure current :2.5A, 5A, 10A, 20A, 50A Accuracy :±0.2%(full range) Data Storage :255 Display :LCD Resistance display: 4 1/2 bits Maximum resolution :0.1μΩ Maximum Power Dissipation :1500W Inputting10A test current
Temperature: -5°C~40°C Humidity: <95%(25°C) Altitude: <2500m Power supply: 220VAC±10%,45Hz~55Hz. Current output: 0 ~ 10A Voltage measurement: 0 ~ 10V
Ratio Measuremen Range :±0.1% + 2 words (0.9 ~ 500) Accuracy3 :± 0.5% + 2 word (2001 ~ 10000) Usage:Transformer Turns Ratio Tester Lithium battery power supply or 220V AC power supply is self-adapting Function:the minimum 0.0001
TTR Measurement Range: 0.8~10000. Three phase test can be completed within 60 seconds. Voltage measurement accuracy on HV side: 0.05% Voltage measurement accuracy on LV side: 0.1% Phase angle measurement accuracy: 0.1°
Power supply: 220V±10%, AC 50 Hz. Measurement ratio: 1:10000 Connecting way:Y/d;D/y;Y/y;D/d;single phrase Display: LCD Accuracy: 1-999.9 ±0.1% class 1000-9999.9 ±0.5% class
Rating: 0.9~2000 Accuracy:±0.1%(below500) 0.2%(501-2000) Resolution: Minimum is 0.0001 Working power supply: AC 220V±10% 50Hz Applied temperature: -10℃~40℃ Relative humidity: ≤85%, non-condensing
Rating: 0.9~2000 Accuracy:±0.1%(below500) 0.2%(501-2000) Resolution: Minimum is 0.0001 Working power supply: AC 220V±10% 50Hz Applied temperature: -10℃~40℃ Relative humidity: ≤85%, non-condensing
Test range wide: 0.9-6000 Minimum Resolution: 0.0001 Rating: 0.9~10000 Accuracy:±0.1%(below500) 0.2%(501-2000) 0.5%(2001-10000) Resolution: Minimum is 0.0001 Power supply: AC 220V±10% 50Hz
Input power supply :220V AC, 50Hz±1%, supplied by alternating current or generator Printer :WH-A7 mini-type thermal printer Accuracy :Cx:±(reading×1%+1pF) tgδ: ±(reading×1%+0.00040) Computer interface :Standard RS232 interface Test current range :Maximum output current: 200mA
Current output:≤200mA Power supply: AC 220V ±10%,50Hz or generator power HV output: 0.5~10kV,45Hzand 55Hz LV Output voltage: 3~50V LV Output current: 3~30A
Test Current Range: 10μA~1A Relative Humidity: <90% Voltage range: 0.5~10kV Max output current: 200mA Frequency Accuracy: ±0.01Hz
Output voltage:0~80KV (optional) Voltagedistortion rate:<3% Booster capacity:1.5KVA Measuring accuracy:±3% Supply voltage:AC220V±10% 50Hz±1 Hz Power:200W
Input voltage :AC 220V Output voltage :AC 0~80kV Voltage boosting speed :2kV/s±10% Accuracy degree :3 Number of times of continuous test :1~9 Data storage :Can store 100 groups data
Step-up transformer capacity 1.5 kVA Output voltage 0~100 kV Environment temperature 0~40℃ Relative humidity ≤85% Supply frequency 50 ± 5 Hz Power consumption <200 W
Input voltage: AC 220V±10% Output voltage: AC 0~80KV Voltage boosting speed: 2KV/s±10% Accuracy degree: 3 Humidity: ≤80%RH
Power supply: AC220V ±10%、50HZ ±5% Measurement rang: AC 0KV~80KV Voltage regulating speed: 2.5KV/S±10% Clearance of cup: 2.5mm (diameter of cup proof stick) Finite current: 5mA
Amount of electrolysis water: 10ug~1000ug Accuracy: ±2ug; >1000ug ,0.2% Measuring range: 0ug~100mg Resolution:0.1ug Maximum electrolysis speed: 40ug/s Power supply: AC220V±20%
Power: <500W Supply voltage: AC220V±10% Relative humidity: <85% Accuracy: 0.5% Resolution: 0.1℃
Power Supply: AC220V ± 20% ; 50HZ ± 10% Repeatability: 0.025X Resolution: 0.1°C Precision: 0.5% Relative Humidity: ≤ 85% RH
Supply voltage: AC220V±10% Power: <500W Relative humidity: <85% Accuracy: 0.5% Resolution: 0.1℃
Power: AC220V±10% AC HV output: 400V~2200V ±2% interval 100V 50VA DC HV output: 200V~600V ±2% interval 50V Distance between HV andLV: 2mm Liquid capacity: About 40ml
Vacuum Degree: -0.08~-0.099 Mpa Working Pressure: ≤0.5 Mpa Temperature Range: 20~80℃ Power Supply: 380V 50Hz 3Ph(as per user,s option) Continuous Working: ≥168H
Temperature control area: 6 loops Program rise rate: 0.1~40℃/min Start sampling: Manual, auto Number of detectors: 5: FID, TCD, ECD, FPD, NPD (optional) Communication: IEEE802.3
Voltage output: >20V Power supply: AC220V±10%,50Hz Current output: ≥1A Power: 180W Humidity: ≤80%RH
Environment Temperature: -10℃~50℃ Measuring Range: 0~20mΩ Resolution Ratio: 0.1µΩ Output Current: 100A,80A,50A,30A Test Line: Resistance less than 10mΩ
Power supply :AC220V±10% 50Hz Measurement range :0~1999 μΩ Resolution :1μΩ Measured current :DC 100A Accuracy :0.5%±1d Display mode :Current: 3-1/2 LCD Resistance: 3-1/2 LCD
Power supply :AC220V±10% 50Hz Measurement range :0~2999.9μΩ Measured current :DC 50A, 100A, 150A, 200A fixed output Accuracy :±(0.5% rd+2d) Continuous working time :5s~599s
Power supply :AC220V±10% 50Hz Measurement range :0~2999.9μΩ Measured current :DC 50A, 100Afixed output Accuracy :±(0.5% rd+2d) Continuous working time :5s~599s Power of the whole machine :600W
Power supply :AC220V±10% 50Hz Measurement range :0~1999 μΩ Resolution :1μΩ Measured current :DC 50A,100A, 150A, 200A fixed output Accuracy :0.5%±1d
External trigger test range: 0.01ms ~ 200000ms Voltage output: DC20 ~ 270V(adjustable) Current output time: 0.01~10 s (settable) Operating environment: -20℃~+50℃ Relative humidity: ≤ 9 0%
Input power :220V±10% 50Hz±10% Insulation resistance :>2MΩ Output power :DC30~250V digitally adjustable /20A (Instantaneous work) Dielectric strength: Power to chassis frequency voltage withstands 1.5KV, 1 min, no flashover and arcing. Current : Range 20.00A, resolution 0.01A
Output power :DC30~250V digitally adjustable/20A (Instantaneous work) Current :Range: 20.00A, resolution: 0.01A Insulation resistance :>2MΩ Atmospheric pressure :86~106kpa ℃ Time :Range: 4000.0ms, resolution: 0.1ms
Input power :220V±10% ,50Hz±10% Atmospheric pressure :86~106kP Internal power :220V/10A Current :20A ,Resolution: 0.01A Time :4000.0ms ,Resolution: 0.1ms
Power supply :AC220V+15%,50Hz Measurement range :10-4~10-1 Pa Electric field voltage :20KV Magnetic field voltage :1600V Accuracy :5%
Input power :three-phase four-wire AC380V Output voltage and current :DC operating voltage output DC 0-260V Three-phase :AC100V output (fixed value) AC voltage output :AC 0~400V, 220V,current﹤10A Single-phase :AC220V output (fixed value, socket)
Power : 220V±10% Voltage :DC15V~220V Current :0~10A Designed for :inspect and repair high-voltage circuit breakers
Relative humidity: must less than 80% Resistance: 0.5 ohm to 2.5k ohm Voltmeter Accuracy: 0.5% Ammeter Range: internal: 0.000~150.0A Ammeter Accuracy: 0.5% Stopwatch Resolution: 0.1mS
Output accuracy :0.5 magnitude Phase current output (effective value) :0~40A Frequency range (base wave) :20~1000Hz Output accuracy :0.5magnitude Maximum output of load voltage :20V
Frequency range ( fundamental wave): 20~1000Hz Accuracy: 0.5 Switching value input: 8 loops Switching value output: 4 pairs Time measurement: 0.1ms~9999s
Power source: AC 220V±10%, 50/60Hz Phase: 0--360 ° Accuracy: 0.1 ° Frequency range: 0--1000Hz Accuracy: 0.001Hz Harmonic times: 2--20 times
Power voltage: AC220V±10% or AC110V±10%, 50/60Hz±10% Time measurement: 0.1ms-999999.999s Output frequency: 0-1050Hz Superposed harmonic wave: 0-21times
Power supply: AC220V±10% 50Hz Work Environment: Temperature:-10℃~40℃ Humidity: ≤85% AC Output voltage: 0~220V/3A Digital millisecond meter: 0~99.9999s
Power supply :AC220V±10%,50Hz Output :0~180Vrms,12Arms,36A(peak value) Voltage measurement accuracy :±0.1% CT Ratio Range :1~40000 Burden accuracy :0.2%±2mΩ
Input supply voltage :AC220V±10%,50Hz Test use :CT, electromagnetic PT Output :0~180Vrms,12Arms,36A(peak) Voltage measurement accuracy :±0.1%
Power supply :AC380V AC220V 5% or 10% error curve :Accuracy ≤1.0% CT ratio test :Range 5~25000A/5A(5000A/1A) PT ratio polarity test :Range 1~10000 Primary current injecting :Current injecting time 5 min
Power supply :AC 220V±10% or AC 110V±10% Excitation voltage output :0-2500Vrms Excitation current output :0-5Arms (20A peak-value) Accuracy :≤0.5% (0.2%RD+0.3%RG) Accuracy:≤0.5% (0.2%RD+0.3%RG)±0.1VA
Power Voltage/Frequency :220V±5V/50Hz±0.5Hz Altitude:<2500m In-phase component (%):0.0001~200.0 ,Resolution:0.0001 Working Load Current :TO对TX<0.12Ω cosΦ=1 In-phase Component :ΔX=±(X×2%+Y×2%)±Dx (with Class 1 to spare)
Power supply :AC220V±10%,50Hz±10% Output capacity of voltage control section :7KVA(250V 30A) can be extended as requirement Reaching Standard :Class 2 Fineness of voltage regulator :Better than 0.04V Can auto :measure the transformer,switch the current, voltage load box
Working mode: LV pulse, pluse current, multiple pulses. Precise locating error: ±0.2m Sampling frequency: 100 MHz, 50 MHz, 25 MHz, 12.5 MHz, 6.25 MHz Maximum working distance: 60KM Test blind zone: 5m
DC voltage is up to 32kV Each stall of voltages is 16 / 32kV, output can up to 1536 J impact energy Discharge cycle can be adjusted within 3-12 seconds Flash over faults in power cable with a variety of 220V-220KV voltage level It is a one body trolley structure, easy handling at site
Relative humidity: RH≤85%(25℃) Power: AC220V±10%DC12V(7AH) Display mode: 12.1 inch LCD (Windows XP) Signal frequency: 15KHz sine wave Output power: Pomax≥100W
Way of working :Peak method, valley method, A-frame method Cable routing :Direct / Coupling / Induction Cable Identification :Direct Connect (power cut) / coupling (has power) Power Supply :Rechargeable Batteries Operating Freq :Low freq, Mid Freq, Hi freq, RF, 50Hz
Signal generator :Power supply: AC220V 50HZ Signal receiver power: 1.5KVA Power regulation mode: intermittent modulation Detection direction and size
Jaw size :Internal diameter of closure≥125mm Power :1.0KVA (Intermittent instantaneous) Recognition method :Determined according the direction of hand swing Big jaw suitable for kinds of cables
The longest testing distance :32km, 100KM for the open-wire line Testing .dead zone :1m Resolution of reading :1m Power dissipation :5VA Electric cable:voltage of 1KV-35KV
Sampling frequency: 200MHz Gain range: 0-70dB Low voltage impulse voltage: 32V Max.resolution: 0.4m Dead Zone: 2m Communication interface: USD, Bluetooth etc. (Optional)
Measurement voltage :10V-500kV (customized) Wireless transmission distance :Stadia distance 150M Display Accuracy :Quantitative measurements≤5° Phase angle resolution :1° Display :LCD
Measurement voltage :10V-500kV (customized) Wireless transmission distance :Stadia distance 150M Display Accuracy :Quantitative measurements≤5° Phase angle resolution :1° Display :LCD
Power Supply :DC6V Alkaline Dry Battery (1.5V AAA X 4) Test Method :Clamp CT, Integral Method Display Mode :4 digital LCD display, backlight function, suitable for dark place. Sampling Speed :About 2 times/second Resolution :0.1mA
Power Supply :DC6V Alkaline Dry Battery (1.5V AAA X 4) Test Method :Clamp CT, Integral Method Circuit Voltage :Test for the circuit below 60KV (operated with insulation rod) Overflow Display :Exceed measurement range overflow function: “OL A” symbol display
Power supply :3 phase, AC380V±10%, 10A, 50Hz (effective value) Anti interference :Z0: Total zero sequence impedance of a line 1 phase Protection function :Over-current, over-voltage, grounding protection. THD :Sine wave,<2%. Measurement resolution Capacitance :0.01μF
Longest measured distance :32km (100km for open wire ) Power consumption :5VA Test results auto displayed :by LCD A/D sampling speed is 100MHz, resolution is 1m detection blind area is 1m
Power supply :AC 220V ,Built-in rechargeable battery Battery performance :Charging time : 20 hours ; can work for 10 hours Purity :Accuracy:±0.5% Dew point :Response time(+20℃) H2S :Stability:0~200ppm
Power: 220V 50Hz Measurement range(SF6):0.1ppm~1000ppm(volume ratio) Indication method :LCD, digital, sound & light alarm Alarm setting range :0.1ppm~1000ppm (volume ratio) Preheating time :2 min Response time :<10S
Minimum Detection Amount :1(×10-6volume ratio) Detection Range :1~1000(×10-6volume ratio) Response Time:<1 second Recovery Time:<10 seconds Display Value Error: ≤±3%
Dew Point Range :-80℃ — +20℃ Measuring Accuracy :±0.5℃ Moisture Range :0.05— 23100 μL/L Communication method :USB,Equipped with host computer data management software Measuring time :3-5 Minutes
Measurement range(SF6):0.1ppm~1000ppm(volume ratio) Indication method :LCD, digital, sound & light alarm Alarm setting range :0.1ppm~1000ppm (volume ratio) Preheating time :2 min Response time :<10S
Measurement range(SF6):0.1ppm~23700ppm Dew Point Precision: ±2℃ Repeatability: ±0.2℃ Gas flow: SF6 adjusted at 0.7~0.9L/min Output port: standard USB
Power supply :AC 220V, Built-in rechargeable battery H2S Measuring range:0~100ppm SO2 Accuracy:±0.5% CO The minimum detectable value:≤1ppm Battery performance :Charging time : 20 hours ; can work for 10 hours
Power supply :AC 220V ,Built-in rechargeable battery Battery performance :Charging time more than 20 hours , can use 10 hours Measuring Range :0%~100% Accuracy :±0.5% Measuring time :<2min.
Power: 220V 50Hz Measurement range(SF6):0.1ppm~1000ppm(volume ratio) Indication method :LCD, digital, sound & light alarm Alarm setting range :0.1ppm~1000ppm (volume ratio) Preheating time :2 min Response time :<10S
Working voltage :AC220V, 50Hz Power :50W Pressure measurement resolution :0.001MPa Accuracy :0.2 Pressure measurement range :0~1MPa Storage Capacity :Save 50 test results at the same time
Power supply :DC 3V, two alkaline batteries Maximum sensitivity :R12, R22, R134a are approved by (14 g / year) Usage time of probe :About 20 hours Usage time of battery :About 30 hours under normal use Working method :Continuous, unlimited
Output Voltage: DC 500V~2500V Accuracy output voltage: 4MΩ~ 100MΩ, 0~+10% HV short-circuit current: ≥1mA Power supply: 8 AA batteries AC/DC dual-use Automatic conversion range, dual-scale display
Output Voltage: DC2500V DC5000V Accuracy output voltage: 20 MΩ~ 100MΩ, 0~+10% 40 MΩ~ 200MΩ, 0~+10% HV short-circuit current: ≥1mA Power supply: 8 AA batteries Automatic conversion range, dual-scale display, LED display
Output Voltage: DC 500V, 1000V, 2500V, 5000V Accuracy output voltage: 4 MΩ~ 20MΩ, 0~+10% 8 MΩ~ 40MΩ, 0~+10% 20 MΩ~ 100MΩ, 0~+10% 40 MΩ~ 200MΩ, 0~+10% HV short-circuit current: ≥3mA Power supply: 8 AA batteries
Output Voltage: DC 2500V, 5000V, 10000V Accuracy insulation resistance: 5M~100G ±5% 10M~200G ±5% 20M~400G ±5% HV short-circuit current: ≥1mA Power supply: 8 AA batteries
Function: Insulation resistance test, voltage test Base conditions: 23°C±5 °C, below 75%rh Rated voltage(V): 250V; 500V; 1000V; 2500V; 5KV; 10KV Test voltage: rated voltage× (1 ±10% ) Insulation Resistance Range: 0.01MΩ~1000G Ω
Rated Testing Voltage: 50V, 100V, 250V, 500V, 1KV, 20~19999uL/L.5KV, 5KV, 10KV Upper Limit of Measuring Range: 100GΩ ~ 10TΩ Lower Limit of Measuring Range: 0.1MΩ Power supply: 14.8V lithium battery Voltage resistance: AC10.0kV 50Hz 1min Insulation resistance: > 500 MΩ (between the test line and machine case)
DC :8×1.5V(AA,R6) battery AC :220V/50Hz Power dissipation :quiescent power dissipation≤160mW; Maximum power≤2.5W Short-circuit current :>1.6mA Output voltage grades :100V,250V,500V,1000V
DC :8×1.5V (AA, R6) battery AC :220V/50Hz Power dissipation :quiescent power dissipation≤160mW; Maximum power≤2.5W Voltage/Load :2500V/20MΩ Resolution :0.01MΩ,0.1MΩ,1.0MΩ,10.0MΩ Output voltage grades :500V,1000V,2000V,2500V
DC :8×1.5V (AA, R6) battery AC :220V/50Hz Power dissipation :quiescent power dissipation≤160mW; Maximum power≤2.5W Voltage/Load :2500V/20MΩ Resolution :0.01MΩ,0.1MΩ,1.0MΩ,10.0MΩ Output voltage grades :500V,1000V,2500V,5000V
Power supply: Rechargeable lithium battery 5.2Ah Rated voltage: 250V, 500V, 1kV, 2.5kV, 5kV Output voltage accuracy: (5%-10%) ±10V Measuring range: 0.50MΩ~2.00TΩ Short circuit current:>5mA Filter test mode: 10S, 20S, 30S, 40S for choice
Power Supply: Rechargeable lithium battery 6.2Ah Rated Voltage: 250V, 500V, 1KV, 2.5KV, 5KV, 10KV, 15KV Output Voltage Accuracy: (5%~10%) ±10V Output Short Circuit Current: ≥7mA Voltage Test Range: AC/DC Voltage Test Accuracy: ±10%rdg±10nF
Test voltage: 0.25KV-20KV Resistance measurement range: 0.5~1999G Ω Calibration voltage of GΩ range is 2.5kV Calibration voltage of MΩ range is 0.5kV Relative humidity : 20 ~ 90%
Test voltage: 0.25KV-20KV Resistance measurement range: 0.5~1999G Ω Calibration voltage of GΩ range is 2.5kV Calibration voltage of MΩ range is 0.5kV Relative humidity : 20 ~ 90%
Test voltage: 0.25KV-20KV Resistance measurement range: 0.5~1999G Ω Calibration voltage of GΩ range is 2.5kV Calibration voltage of MΩ range is 0.5kV Relative humidity : 20 ~ 90%
Test voltage: 0.25KV-20KV Resistance measurement range: 0.5~1999G Ω Calibration voltage of GΩ range is 2.5kV Calibration voltage of MΩ range is 0.5kV Relative humidity : 20 ~ 90%
Number of Channels: 4U/4I Phase-to phase voltage: 1.0V~2000V. Phase-to-neutral voltage: 1.0V~1000V. Number of Transient: 150 sets. Frequency: 40Hz~70Hz.
100A, 500A and 1000A clamp meters are optional Working power supply is AC57 ~ 450V Store 10000 groups of energy meters U disk storage is supported High resolution TFT color LCD screen display
Secondary phase voltage range: 5-500V Secondary current range: 5mA-10A Primary current range: 100mA-5A Simultaneous measure 1-3 circuit AC current Measurement voltage range: 1~500V
Voltage fluctuation: 0.1%~10.0% Active Power: 0.05~700KW Apparent Power: 0.05~700KVA 3 Phase Voltage: 10~700V 3 Phase Current: 0.5~1000A
Phase voltage range: 5-500V phase current range:5mA-10A Simultaneous measure 1-3 circuit AC voltage Simultaneous measure 1-4 circuit AC current 12 hours continuous use Measurement voltage range: 1~500V
3.5 inch TFT color display Measuring Voltage Range: 1~500V Measuring Current Range: 0.001~10A Frequency: 45~65Hz Reactive Power: 0.001~5000VAR
Secondary windings can stand 1000V/50Hz ≥10MΩ between the two voltage input terminals Two voltage input terminals can stand Sinusoidal AC Voltage 500V/50Hz for 1min Device with high-contrast LCD screen Wave forms of measured signal: sine wave, β=0.02
Current resolution up to 0.1mA Voltage resolution up to 0.1V Device with high-contrast LCD screen Wave forms of measured signal: sine wave, β=0.02 Measuring Amplitude range: 100~220V, 0.5~1.5A
Communication Interface: USB Measure time: 2s/time Date Storage: 1500 sets Clamp: Φ8mm Current: AC 0.0mA~20.0A Voltage: AC 0.00V~600V
Communication Interface: USB Measure time: 2s/time Date Storage: 1500 sets Clamp: Φ8mm Current: AC 0.0mA~20.0A Voltage: AC 0.00V~600V
Communication Interface: USB Measure time: 2s/time Date Storage: 1500 sets Clamp: Φ8mm Current: AC 0.0mA~20.0A Voltage: AC 0.00V~600V
Communication Interface: USB Measure time: 2s/time Date Storage: 1500 sets Clamp: Φ8mm LCD: 240dotsX160dots Current clamp length: 2m
Input voltage: Three-phase four-wire 3×380(220)V 50Hz Output Voltage: Three-phase four-wire 3x(0~380)/(0~220) Maximum output capacity: 3x300VA Insulation resistance: ≥22MΩ Pressure test: 1.0kV/min
Power Supply :DC 9V(Zn-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours ) Test Voltage Wave :Sine wave Test Frequency :128Hz/111Hz/105Hz/94Hz(AFC) Short-circuit Test Current :AC 20mA max Open-circuit Test Current :AC 40V max
Power Supply :DC 9V Zi-Mn dry battery LR14 1.5V 6 PCS LCD :124mm×67mm(black light) Accuracy :±2%rdg±3dgt Date Storage :300 sets Cable resistance verification :Automatic calibration
Range:Ground Resistance:0.01Ω-2000Ω;Ground voltage:AC 0~600V 1:Ground resistance test 2:Ground Voltage test 3:Low resistance test Power Supply :DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )
Power supply :AC220V±10%、50Hz Work Mode :Continuous Display :Three and half LCD display Measuring Radius :50 m Measurement Range :1~1999mΩ
Power supply :220V±10% 50±5 Hz The test terminal of ground wire :2~5 terminal Accuracy :Class 0.5 the measuring range :0~199.99mΩ Test current :20A,30A
Power supply and power dissipation DC: 8×1.5V(AA,R6) battery AC: 220V/50Hz Ground voltage (frequency virtual value) :≤ 5V error ≤ ± 5% Maximum power dissipation :≤2W Resolution :0.001Ω、0.01Ω、0.1Ω、0.01V
Power supply :8 AA NiMH rechargeable batteries or regular AA batteries Storage capacity :200 groups Jaw size :Φ50mm Minimum resolution :0.01Ω Double clamp method :0.01Ω~200Ω
Supply voltage :AC220V±10% Voltage frequency :50Hz±5% Input fuse :200mA Maximum power :3W Signal current measurement sensitivity :0.5mA
Power Source :6VDC (4 ×5# alkaline battery) LCD display :4-digital LCD:47×28.5mm2 Protection Level :Double insulation Structural Feature :In the jaw way Shift :Automatic
Power supply :AC 220V±10%,50Hz Anti-jamming capability :Anti- frequency 50Hz voltage 10V Current output gear :3/2.5/2/1.5/1A Impedance measurement range :0~200Ω Resolution :0.001Ω
Power supply :AC220V±10%,50Hz Anti-jamming capability :Anti- frequency 50Hz voltage 10V Current output gear :5 / 4.5 / 4 / 3.5 / 3 / 2.5 / 2 / 1.5 / 1A, 0.5A/gear, total 9 gears Resolution :0.001Ω Impedance measurement range :0~200Ω (Including current pile impedance)
Power: DC or AC 220V, 50Hz. Reference voltage input range: 50Hz 、 30 ~ 100 800x480 Color LCD graphic displays Leakage current 100μA ~ 10mA(peak value) Measurement voltage range 30 ~ 100V
Power consumption: 4W AC power supply: AC220V ±10%,50Hz ±1% Reference voltage input range (peak value): 10V~200V Angle measurement range: 0°~90°
Small in volume, light in weight Output impulse current waveform: 8/20μs Current amplitude: >100A Applies to test if the discharge counter normally work
Small in volume, light in weight Output impulse current waveform: 8/20μs Current amplitude: >100A Applies to test if the discharge counter normally work
DC breakdown voltage (V sdc): (20~1700)V Insulating resistance: 6M Ω(500V) Voltage withstand: AC 1.5kV 50HZ 1min Power supply: DC 12V dedicated power supply Leakage current (I 0.75U 1mA): (0.1~199.9) μA
DC breakdown voltage (V sdc): (20~1700)V Insulating resistance: 6M Ω(500V) Voltage withstand: AC 1.5kV 50HZ 1min Power supply: DC 12V dedicated power supply Leakage current (I 0.75U 1mA): (0.1~199.9) μA
Salt density measuring range: 0.001~9.999mg/cm2 Salt density measuring accuracy: ≤±1% Temperature measuring range: 0~100 ℃ 320x240 color TFT LCD screen display Power supply: AC: 220V ±10% ; DC: 6,number 5, 1.5V dry batteries
Power supply: AC220V ±10%, 50Hz Power: 180W Humidity: ≤ 80% LCD Display
Measuring voltage range: 0 ~ 40kV Measurement error: ≤±1% Resolution: 0.01kV Sampling rate: 10 times /seconds Working current: ≤120mA ( handset ), ≤40mA ( detector )
Wide test range: 5~6000Ah Compatible for single cell of 2V, 6V and 12V Resistance range: 0.00mΩ ~ 100mΩ Voltage range: 0 V ~220V Measuring data memory: 3000 cells Working time: 5-6 hours
Power source :12V, chargeable Li-battery Consumption :8 hours standby mode Min. resolution :Internal resistance: 0.001mΩ Voltage: 1mV Storage volume :64Mbit Flash + 8G SD card LCD :5”colour touch screen
Single voltage range: 1-20V, to meet the 2V, 6V, 12V monomer monitoring Display all test data: current, voltage, discharge time, capacity, etc Item No : WXBO-4815 /WXBO-4830/ WXBO-2206/ WXBO-6006 /WXBO-60010
Group Voltage Range :20~60V Discharge Current :0~150A Internal Memory :8Mbit FLASH PC Communication :RS232 socket Accuracy discharge current: ≤±0.5% / group voltage: ≤±0.5% / battery voltage: ≤±0.5%
Power Supply Voltage :single-phase3-wire 220Vac (-20%~+30%), frequency: 45~65Hz AC Input :standardsocket, available for 1~1.5 mm2 cable Altitude :Available below 4000m Internal Memory :8 Mbit FLASH
Type: WXCE820/WXCE840/WXCE860 Max Extension Current :720A Max(120A internal + 600A external) Discharge Mode :Constant Current/Power/Resistance Accuracy :Current: ≤±0.5%, Group Volt: ≤±0.5%, Cell Volt: ≤±0.5% PC Communication :RS232 serial communication
Discharger & Charger for 1.2V/2V/6V/12V single battery Display: 5.7 inch LCD touch screen Support RS232 PC Software Support up to 9cycles discharge/charge autorun
Display: 7 inch color touch screen LCD Power Supply: AC 220V ±10%, 50Hz Output Voltage: AC 23V ±10%, 50Hz Maximum Output Current: 20A Resolution: 0.001uF
Power supply:AC 220V±10%,50Hz Output voltage (open circuit):AC 23V±10%,50Hz(capacitance); AC 3V±20%,50Hz (inductance) Maximum output current:20A Output short circuit protection: Automatic Inductance measurement range:100μH~50H
Power:AC220V±10% 50HZ Output voltage accuracy :±(1.0%R±2D) Output current accuracy : ±(1.0%R±2D) Ripple factor :≤0.5% Working mode :Intermittent use, 30 minutes under rated load
Power :AC220V±10%,50Hz±1% Output voltage indication accuracy :<1 class 0.75 times output voltage indication accuracy :<1 class,With latch Altitude :1500m below Way of working :Intermittent use for 30 minutes
Power supply:Single phase :220V Or three phase :380V±10%, Frequency:50Hz±5% AC effective value Rated output voltage:≤0~220kV Output frequency :30~300Hz Frequency adjustment :0.1Hz
Frequency Power Source: 3kv~60kv Divider: 50kv~800kv Rated Output Voltage:0~1000kv Power Supply: single phase220V / 3 phase 380V
Power:AC220V±10%, 50Hz±1% Ripple factor : ≤0.5% 0.75 times output voltage indication accuracy : <1,with latch function Working mode :discontinuously work for 30 minutes Altitude :<1500m
Withstanding Voltage Test Output Voltage: AC: 0.05~5.00KV DC: 0.05~6.00KV Current Test Range: AC: 0.00~10.00mA DC: 0.00~5.00mA
Withstanding Voltage Test Output Voltage: AC: 0.05~5.00KV DC: 0.05~6.00KV Current Test Range: AC: 0.00~10.00mA DC: 0.00~5.00mA
Power Requirements: AC:220V±10% 50Hz/60Hz ± 3Hz Test Accuracy: ± (5%+3 words) Test Time: (0.0~999)s 0.0=continuous test Transformer Capacity: 100VA, 500VA, 1000VA. Interface of PLC: Optional